专业体育直播_高清在线观看

Evoqua United States - Canada - EN

Ballasted Clarification Technology Provides Low Cost Solution that Meets Phosphorus Limits

CoMag system exceeds performance parameters while providing high-quality effluent

Challenge

Prior to 2007, the Concord, Massachusetts wastewater treatment plant operated under a NPDES permit that allowed a seasonal phosphorus limit of 0.7 mg/L.  However, with the issuance of a new five-year permit with a phosphorus limit of 0.2 mg/L and the probability that future limits could reach as low as 0.05 mg/L, the city of Concord needed a treatment solution that would be reliable and cost-effective over the long term.

 

Solution

​When compared to dissolved air floatation, media filtration and sand ballasted technologies, Concord’s consulting engineers recommended the CoMag® System​ from Evoqua Water Technologies. Key benefits include:

  • Ability to provide effluent TP values from 0.2 mg/L to ≤ 0.05 mg/L simply by adjusting the flocculent dose.

  • Reliability of operation — conventional flocculation and coagulation coupled with high rate clarification and no filters to clog or backwash.

  • Capital cost savings given its small clarifiers and footprint.


The CoMag® System Overview

Simple, reliable and proven, the CoMag® System from Evoqua uses magnetite to ballast conventional chemical floc, enhancing settling rates to dramatically increase the performance of wastewater treatment facilities. Primarily used to improve primary and/or tertiary treatment, the CoMag System easily integrates with planned or existing facilities, making it easier than ever to solve today’s operational and environmental challenges.

At the Concord WWTP, the CoMag System includes six steps:

  • Conventional chemical flocculation with Ferric, Alum or PAC
  • Infusion of the floc with fully inert, finely ground, nonabrasive magnetite
    (Fe3O4) to increase the specific gravity of the floc
  • Coagulation to bind the floc together
  • High rate clarification in traditional but smaller clarifiers
  • Sludge recycled for stable operation, upset prevention and pin floc capture
  • 99+% recycle and reuse of magnetite for low operating costs

Results

Installed in 2007, the CoMag® System exceeded all performance parameters — achieving TP down to 0.2 mg/L, with daily capacity of 1.25 (4.73)/4.4 (16.7) MGD(MLD).



The system now plays an integral role in a larger facility upgrade that includes improvements to the headworks, disinfection system, plant utilities, controls and other processes. Additionally, its high-quality effluent enables the facility to utilize smaller, more cost-effective UV disinfection system.​

Request a Proposal

Contact Evoqua for more information on available solutions

Request a Proposal
足球直播网|免费NBA直播|足球直播|中超直播|法甲直播|德甲直播|欧冠直播|免费无插件-足球直播网 球迷网nba直播吧-APP最新版-安卓版/苹果版下载-2024 咪咕体育直播足球-APP最新版-安卓版/苹果版下载-2024 如何看体育直播-APP最新版-安卓版/苹果版下载-2024 体育现场直播女排比赛|免费NBA直播|足球直播|中超直播|法甲直播|德甲直播|欧冠直播|免费无插件-体育现场直播女排比赛 北京体育直播在线观看|免费NBA直播|足球直播|中超直播|法甲直播|德甲直播|欧冠直播|免费无插件-北京体育直播在线观看 直播365足球-APP最新版-安卓版/苹果版下载-2024 cctv5体育直播-APP最新版-安卓版/苹果版下载-2024 企鹅直播体育直播-APP最新版-安卓版/苹果版下载-2024 近期足球直播|免费NBA直播|足球直播|中超直播|法甲直播|德甲直播|欧冠直播|免费无插件-近期足球直播